Reliability of the smartphone application inclinometer and flexicurve in measuring thoracic kyphosis

dc.contributor.authorElpeze, Gonul
dc.contributor.authorUsgu, Gunseli
dc.contributor.authorYigit, Sedat
dc.date.accessioned2023-08-16T08:07:23Z
dc.date.available2023-08-16T08:07:23Z
dc.date.issuedMAR 8 2023en_US
dc.departmentHKÜ, Sağlık Bilimleri Fakültesi, Fizyoterapi ve Rehabilitasyon Bölümüen_US
dc.description.abstractIntroduction: This study examined the inter-and intra-rater reliability of the smartphone inclinometer app (SPI) and flexicurve (FC) for assessing the kyphotic angle in individuals with thoracic kyphosis (TK). Methods: This study was conducted with 60 subjects (35 males, 25 females) aged 18 to 25 who presented to Kalyon Medical Center, Gaziantep, Turkey, between December 2021 and March 2022. The subjects were evaluated by two independent assessors using FC and SPI to measure the TK angle. The intraclass correlation coefficient (ICC) was analysed at a 95% confidence interval. The level of agreement between the methods was checked using Bland-Altman analysis. Results: Inter-and intra-rater measurements were strongly correlated (ICC 0.945 and 0.964, respectively). On the Bland-Altman plots, the FC showed poor agreement with the SPI app (mean difference, 19.81?? ?? 2.8??). The mean kyphotic angles were 45.15 ?? 6.07?? and 25.34 ?? 4.96??, respectively, as measured by the SPI and FC. Conclusion: This study demonstrated good intra-and inter-rater reliability of the SPI app and FC for the measurement of the spinal curvature (TK) angle in the sagittal plane. A weak agreement was discerned between the SPI and FC methods.en_US
dc.identifier.citationElpeze, G , Usgu, G & Yigit, S . (MAR 8 2023) . Reliability of the smartphone application inclinometer and flexicurve in measuring thoracic kyphosis . Cureus Journal Of Medıcal Scıence . (15, 3 ss. ) . https://doi.org/10.7759/cureus.35886 .en_US
dc.identifier.doi10.7759/cureus.35886
dc.identifier.issn2168-8184
dc.identifier.issue3en_US
dc.identifier.orcid0000-0003-4269-5210en_US
dc.identifier.pmid37033529
dc.identifier.urihttps://doi.org/10.7759/cureus.35886
dc.identifier.urihttps://hdl.handle.net/20.500.11782/3243
dc.identifier.volume15en_US
dc.identifier.wosWOS:000980801600031
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherCUREUS INCen_US
dc.relation.ispartofCureus Journal Of Medıcal Scıence
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/restrictedAccessen_US
dc.subjectflexicurveen_US
dc.subjectsmartphoneen_US
dc.subjectintra-rater reliabilityen_US
dc.subjectinter -rater reliabilityen_US
dc.subjectthoracic kyphosisen_US
dc.titleReliability of the smartphone application inclinometer and flexicurve in measuring thoracic kyphosis
dc.typeArticle

Dosyalar

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: