Damage Evaluation of Masonry Buildings after Van Earthquakes in 2011

dc.contributor.authorGuney, Deniz
dc.contributor.authorKuruscu, A. O.
dc.contributor.authorArun, G.
dc.date.accessioned2019-11-19T11:29:23Z
dc.date.available2019-11-19T11:29:23Z
dc.date.issued2016
dc.departmentHKÜ, Güzel Sanatlar ve Mimarlık Fakültesi, Mimarlık Bölümüen_US
dc.description.abstractIn 2011, Van City, located in southeast Turkey, was hit by two destructive earthquakes that caused the loss of life and property. During these earthquakes approximately 4,000 buildings collapsed or were seriously damaged, 644 people were killed, and 2,608 people were injured. In the region hit by the earthquakes there were many houses and public buildings constructed with stone, brick, adobe, and concrete blocks, some of which were heavily affected while others incurred only slight damage. Most of the buildings in the region were built without any design, control, or supervision. In this article, the relationship between damage levels and structural parameters, such as the age of a building, masonry material, construction method, and workmanship quality, affecting the seismic performance of the masonry buildings of this area are evaluated based on site investigation following the earthquakes. This article also includes an overview of the dynamic characteristics of the earthquake and the seismic history of the region.en_US
dc.identifier.citationGüney, ., Kuruşcu, ., & Arun, . (April 02, 2016). Damage Evaluation of Masonry Buildings after Van Earthquakes in 2011. International Journal of Architectural Heritage, 10, 269-280.en_US
dc.identifier.doi10.1080/15583058.2015.1113343
dc.identifier.endpage280en_US
dc.identifier.issn1558-3058
dc.identifier.issn1558-3066
dc.identifier.issue2-3en_US
dc.identifier.scopus2-s2.0-84965121614
dc.identifier.scopusqualityQ1
dc.identifier.startpage269en_US
dc.identifier.urihttps://doi.org/10.1080/15583058.2015.1113343
dc.identifier.urihttps://hdl.handle.net/20.500.11782/802
dc.identifier.volume10en_US
dc.identifier.wosWOS:000374995100014
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherTAYLOR & FRANCIS INCen_US
dc.relation.ispartofINTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/embargoedAccessen_US
dc.subjectadobeen_US
dc.subjectdamage assessmenten_US
dc.subjectfailure mechanismen_US
dc.subjectseismic performance of masonry buildingsen_US
dc.subjectVan earthquakeen_US
dc.subjectvernacular masonry buildingsen_US
dc.titleDamage Evaluation of Masonry Buildings after Van Earthquakes in 2011
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
000374995100014.pdf
Boyut:
1.77 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.56 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: