Developed analytical expression for current harmonic distortion of the PV system’s inverter in relation to the solar irradiance and temperature

dc.contributor.authorAdak, Suleyman
dc.contributor.authorCangi, Hasan
dc.contributor.authorEid, Bilal M.
dc.contributor.authorYilmaz, Ahmet Serdar
dc.date.accessioned2021-01-13T08:01:26Z
dc.date.available2021-01-13T08:01:26Z
dc.date.issued2020en_US
dc.departmentHKÜ, Mühendislik Fakültesi, Elektrik Elektronik Mühendisliği Bölümüen_US
dc.description.abstractThis paper deals with modeling and simulation of the total harmonic distortion of the current (THDI) dispatched from the inverter and connected to nonlinear load. The change of THDI was examined in relation to the ambient temperature (T) and solar irradiance (G).The developed model is being used to extract parameters for a given THDI as a function of temperature and solar radiation. This study outlines the working principle of photovoltaic (PV) panel as well as PV array. Off-grid PV system is modeled by using Matlab/Simulink program, and detailed analytical study has been carried out in this work. The design, modeling and simulation of this study are performed from 50 up to 988 W/m2 for solar irradiance. Harmonic components have negative effects on the steady-voltage stability of the PV system. Therefore, analytical expression is needed for steady-state stability analysis in order to reduce negative effects. Hence, two analytical expressions of THDI were obtained by two new different methods which are statistical package for the social sciences program and genetic expression programming. Eventually, two different methods have been verified by the Matlab/Simulink program in order to find out THDI and demonstrated the effectiveness of the proposed strategy. As a result of this study, it is observed that input current THDI of nonlinear load is too high at low irradiance. It is suggested that active harmonic filters should be used at low irradiance in order to produce better quality energy and avoid damages in the PV system. © 2020, Springer-Verlag GmbH Germany, part of Springer Nature.en_US
dc.identifier.citationAdak, S., Cangi, H., Eid, B., & Yilmaz, A. S. (January 01, 2020). Developed analytical expression for current harmonic distortion of the PV system’s inverter in relation to the solar irradiance and temperature. Electrical Engineering.en_US
dc.identifier.doi10.1007/s00202-020-01110-7
dc.identifier.issn09487921
dc.identifier.orcid0000-0001-6954-7299en_US
dc.identifier.scopus2-s2.0-85091843083
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1007/s00202-020-01110-7
dc.identifier.urihttps://hdl.handle.net/20.500.11782/2224
dc.identifier.wosWOS:000574799700001
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherSpringer Science and Business Media Deutschland GmbHen_US
dc.relation.ispartofElectrical Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectNonlinear loaden_US
dc.subjectPhotovoltaic panel temperatureen_US
dc.subjectPhotovoltaic systemen_US
dc.subjectSolar irradianceen_US
dc.subjectTotal harmonic distortionen_US
dc.titleDeveloped analytical expression for current harmonic distortion of the PV system’s inverter in relation to the solar irradiance and temperature
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
10.1007s00202-020-01110-7.pdf
Boyut:
1.14 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: